Number of bus turnaround cycles EMC_CS0.
WAITTURN | Bus turn-around cycles. 0x0 - 0xE = (n + 1) CCLK turn-around cycles. Bus turn-around time is (WAITTURN + 1) x tCCLK. 0xF = 16 CCLK turn-around cycles (POR reset value). |
RESERVED | Reserved, user software should not write ones to reserved bits. The value read from a reserved bit is not defined. |